ProSim Failure List
La suite “ProSim A320” è in grado di riprodurre la quasi totalità delle avarie presenti sui “FULL FLYGHT SIMULATOR”
ATA 21 Air Conditioning
- Cabin pressure controller failure
- Decompression
- Hot air fault
- Hot air valve
- Hot air valve aft cargo
- Lavatory/Galley fan
- Outflow valve stuck
- Pack overheat
- Pack regulator fault
- Recirculation fans
- Ventilation blower fault
- Ventilation extract fault
- Cabin pressure controller 1 fails.
- Cabin pressure controller 2 fails.
- Pack 1 outlet temperature sensor fails.
- Pack 1 regulator fails.
- Pack 2 outlet temperature sensor fails.
- Pack 2 regulator fails.
- Hot air valve stuck in current position.
- Zone controller primary
- Zone controller secondary
- Hot air fails.
- Cargo ventilation controller fails
- Cargo hot air valve fails.
- Cargo fwd isolation upstream valve stuck closed
- Cargo fwd isolation downstream valve stuck closed
- Cargo aft isolation upstream valve stuck closed
- Cargo fwd isolation upstream valve stuck closed
- Recirculation fan fails.
- Slow decompression.
- Rapid decompression.
- Outflow valve is mechanically stuck in current position.
- AEVC Power supply failure
- Vent inlet valve
- Vent extract valve
- Blower fan fails.
- Extract fan fails.
ATA 22 AutoFlight
- A/THR functionality failed
- FAC failure
- FAC failure resettable
- Failure of FMGC AP function. FD not affected.
- FCU channel failure
- FMGC failure
- MCDU failure
- MCDU recoverable failure
- Rudder travel limiter failure
- Rudder trim channel fails
- Yaw damper actuator failure
- FAC 1 fails.
- FAC 1 fails, but is resettable.
- Rudder travel limiter 1 fails.
- Rudder trim channel 1 fails.
- Reactive W/S det channel 1
- FAC 2 fails.
- FAC 2 fails, but is resettable.
- Rudder travel limiter 2 fails.
- Rudder trim channel 2 fails.
- Reactive W/S det channel 2
- Demonstration of alternate law with protections.
- Demonstration of alternate law without protections.
- Demonstration of direct law.
- FCU channel 1 fails.
- FCU channel 2 fails.
- A/THR functionality of FMGC 1 fails.
- A/THR functionality of FMGC 2 fails.
- Reset A/T inhibited by instinctive disconnect button.
- Failure of FMGC AP 1 function. FD not affected.
- Failure of FMGC AP 2 function. FD not affected.
- Failure to automatically arm TCAS mode during TCAS TA
ATA 23 Communications
Stuck mic
Captain Push-To-Talk stuck.
F/O Push-To-Talk stuck.
ATA 24 Electrical power
- AC bus 1
- AC bus 2
- AC Essential bus
- AC Essential shed bus
- APU Generator
- DC Bat bus
- DC bus 1
- DC bus 2
- DC Essential bus
- DC Essential shed bus
- Eng generator failure
- ESS TR failure
- IDG oil low pressure
- IDG oil overheat
- Static inverter
- TR failure
- DC Battery bus fails.
- DC bus 1 fails.
- DC bus 2 fails.
- AC bus 1 fails.
- AC bus 2 fails.
- Hot bus 1 failure
- Hot bus 2 failure
- AC Essential bus fails.
- DC Essential bus fails.
- AC Essential shed bus fails.
- DC Essential shed bus fails.
- AC Static inverter bus failure
- AC bus 1 26v failure
- AC bus 2 26v failure
- AC ess bus 26v failure
- APU generator fails.
- Reset electric generator 1 disconnected from the engine.
- Engine 1 generator fails.
- IDG 1 oil overheat.
- IDG 1 low oil pressure.
- Reset electric generator 2 disconnected from the engine.
- Engine 2 generator fails.
- IDG 2 oil overheat.
- Generator oil low level
- Static inverter fails.
- TR 1 fails.
- TR 2 fails.
- Transformer/Rectifier unit fails and will not provide DC power.
- AC Essetial bus stuck to alternate
- AC Ess feed from AC Bus 1.
- AC Ess feed from AC Bus 2.
ATA 26 Fire protection
- APU fire
- APU fire detection loop depressurized
- Avionics smoke detected
- Cargo smoke detected
- Eng fire
- Eng fire detection loop depressurized
- FDU failure
- SDCU failure
- Reset cargo bottle 1 discharged.
- Reset cargo bottle 2 discharged.
- Fwd cargo smoke detected.
- Aft cargo smoke detected.
- Smoke is detected in a lavatory
- Reset fire Engine 1 agent 1 discharged.
- Engine 1 fire extinguished with 1 bottle.
- Engine 1 fire extinguished with 2 bottles.
- Reset fire Engine 1 agent 2 discharged.
- Engine 1 fire detection loop A is depressurized.
- Engine 1 fire detection loop B is depressurized.
- Reset fire Engine 2 agent 1 discharged.
- Engine 2 fire extinguished with 1 bottle.
- Engine 2 fire extinguished with 2 bottles.
- Reset fire Engine 2 agent 2 discharged.
- Engine 2 fire detection loop A is depressurized.
- Engine 2 fire detection loop B is depressurized.
- Reset fire APU agent discharged.
- APU fire extinguished with 1 bottle.
- APU fire detection loop A is depressurized.
- APU fire detection loop B is depressurized.
- Engine 1 FDU fails.
- Engine 2 FDU fails.
- APU FDU fails.
- Avionics smoke detected.
ATA 27 Flight controls
- Alignment fault
- Alternate law with protection
- Alternate law without protection
- Direct law
- ELAC failure
- ELAC resettable failure
- Elevator panels jammed
- Flap locked
- SEC failure
- SEC resettable failure
- SFCC channel failure
- Sidestick controls are reversed in pitch/roll axes
- Sidestick failure
- Slat locked
- Stabilizer jam
- Flap Instrumentation postion pickup unit 1 fails
- Flap Instrumentation postion pickup unit 2 fails
- Flaps are locked through WTB.
- Slats are locked through WTB.
- SFCC senses difference between right and left flap extention.
- SFCC channel 1 fails.
- SFCC flap 1 system fails.
- SFCC slat 1 system fails.
- SFCC channel 2 fails.
- SFCC flap 2 system fails.
- SFCC slat 2 system fails.
- ELAC 1 fails.
- ELAC 1 fails, but is resettable.
- ELAC 2 fails.
- ELAC 2 fails, but is resettable.
- SEC 1 fails
- SEC 1 fails, but is resettable.
- SEC 2 fails.
- SEC 2 fails, but is resettable.
- SEC 3 fails.
- SEC 3 fails, but is resettable.
- Yaw damper actuator 1 fails.
- Yaw damper actuator 2 fails.
- Captain sidestick controls are reversed in pitch axis
- Captain sidestick controls are reversed in roll axis
- Sidestick captain fails.
- F/O sidestick controls are reversed in pitch axis
- F/O sidestick controls are reversed in roll axis
- Sidestick captain fails.
- FCDC 1 fails.
- FCDC 2 fails.
- Stabilizer trim actuator fails.
- Jamming of both elevator panels.
- Jamming of right elevator panel.
ATA 28 Fuel
- Center tank pump failure
- Crossfeed valve
- FQI channel failure
- Fuel leak Center
- Fuel leak inner tank
- Fuel leak outer tank
- Fuel valve stuck
- Hp fuel valve stuck
- Wing tank pump failure
- Wing tank temperature advisory
- Wing tank temperatures ECAM
- Wing transfer valve stuck in current position
- FQI channel 1 fails.
- FQI channel 2 fails.
- Left tank pump 1 fails.
- Left tank pump 2 fails.
- Center tank left pump fails.
- Center tank right pump fails.
- Right tank pump 1 fails.
- Right tank pump 2 fails.
- Inner tank temperatures above limit.
- Inner tank temperatures below limit.
- Outer tank temperatures above limit.
- Outer tank temperatures below limit.
- Inner tank temperatures above advisory limit.
- Inner tank temperatures below advisory limit.
- Outer tank temperatures above advisory limit.
- Outer tank temperatures below advisory limit.
- Left transfer valve 1 stuck in current position.
- Left transfer valve 2 stuck in current position.
- Right transfer valve 1 stuck in current position.
- Right transfer valve 2 stuck in current position.
- Engine 1 fuel valve stuck.
- Engine 2 fuel valve stuck.
- Crossfeed valve stuck.
- Fuel leak from left outer tank.
- Fuel leak from left inner tank.
- Fuel leak from center tank.
- Fuel leak from right inner tank.
- Fuel leak from right outer tank.
- Engine 1 hp fuel valve stuck.
- Engine 1 hp fuel valve stuck
ATA 29 Hydraulic power
- Blue hydraulic leak
- Elec blue pump overheat
- Elec hyd pump Blue failure
- Elec hyd pump Yellow failure
- Elec yellow pump overheat
- Eng fire valve failure
- Eng pump failure
- Hydraulic leak
- Hydraulic low reservoir air pressure
- PTU Fault
- Temperature of reservoir exceeds high limit
- Green hydraulic line leaks.
- Temperature of green reservoir exceeds high limit.
- Green low reservoir air pressure.
- Green hydraulic low level
- Blue hydraulic line leaks.
- Temperature of blue reservoir exceeds high limit.
- Blue low reservoir air pressure.
- Blue hydraulic low level
- Yellow hydraulic line leaks.
- Temperature of yellow reservoir exceeds high limit.
- Yellow low reservoir air pressure
- Yellow hydraulic low level
- Reset RAT deployed.
- Engine 1 pump fails.
- Engine 1 fire valve fails.
- Engine 2 pump fails.
- Engine 2 fire valve fails.
- PTU fails.
- Blue Elec hydraulic pump fails.
- Blue Elec pump overheat.
- Yellow Elec hydraulic pump fails.
- Yellow elec pump overheat.
ATA 30 Ice and rain protection
- Anti ice valve fault
- AOA heat power supply fails
- Loss of probe heating
- Pitot heat power supply fails
- Static port heat captain power supply fails
- Static port heat F/O power supply fails
- Static port heat stdby power supply fails
- TAT heat power supply fails
- WHC failure
- Wing anti ice valve locked in current position
- Left wing anti ice valve locked in current position.
- Righ wing anti ice valve locked in current position.
- Engine 1 anti ice valve fails.
- Engine 2 anti ice valve fails.
- WHC 1 fails.
- WHC 2 fails.
- AOA heat captain power supply fails.
- AOA heat F/O power supply fails.
- AOA heat standby power supply fails.
- TAT heat captain power supply fails.
- TAT heat F/O power supply fails.
- TAT heat stdby power supply fails.
- Pitot heat captain power supply fails.
- Pitot heat F/O power supply fails.
- Pitot heat standby power supply fails.
- Left static port heat captain power supply fails.
- Right static port heat captain power supply fails.
- Left static port heat F/O power supply fails.
- Right static port heat F/O power supply fails.
- Left static port heat standby power supply fails.
- Right static port heat standby power supply fails.
- Loss of Captain probe heating.
- Loss of F/O probe heating.
- Loss of standby probe heating.
- Reset icing condition
- Moderate icing in 3 minutes.
- Severe icing in 1 minutes.
- Engine 1 icing.
- Engine 2 icing.
ATA 31 Indicating/Recording system
- DMC 1
- DMC 2
- DMC 3
- DU ECAM Lower
- DU ECAM Upper
- ECP
- FWC failure
- ND failure
- PFD failure
- SDAC failure
- CFDIU power supply failure
- ECAM control panel internal failure.
- SDAC 1 fails.
- SDAC 2 fails.
- FWC 1 fails.
- FWC 2 fails.
- CVR fault
- DMC 1 fails.
- DMC 2 fails.
- DMC 3 fails.
- DCDU Capt power supply failure
- DCDU F/O power supply failure
- Captain PFD fails.
- Captain ND fails.
- F/O ND fails.
- F/O PFD fails.
- Upper ECAM display fails.
- Lower ECAM display fails.
ATA 32 Landing gear
- Autobrake failure
- BSCU brake system failure
- BSCU failure
- Gear does not lock
- Gear locked down
- Gear locked up
- Gear safety valve
- LGCIU failure
- Nose wheel steering
- Wheel brake failure
- BSCU SYS 1 fails.
- BSCU SYS 2 fails.
- Alternate brake fault
- BSCU 1 brake system fails.
- BSCU 2 brake system fails.
- Wheel 1 brake fails.
- Wheel 2 brake fails.
- Wheel 3 brake fails.
- Wheel 4 brake fails.
- Main tyre 1 pressure low.
- Main tyre 2 pressure low.
- Left tyre 1 pressure low.
- Left tyre 2 pressure low.
- Right tyre 1 pressure low.
- Right tyre 2 pressure low.
- Autobrake fails.
- Nose wheel steering fails.
- Reset high brake temperature.
- LGCIU 1 fails.
- LGCIU 2 fails.
- Gear safety valve fails.
- Left gear does not lock.
- Nose gear does not lock.
- Right gear does not lock.
- Gear does not extend when gear lever moved down.
- Gear does not retract when gear lever moved up.
ATA 33
- ADF 1
- ADF 2
- ADR failure
- GPS receiver failure
- ILS 1 Loc or G/S channel receiver failure
- ILS 2 Loc or G/S channel receiver failure
- ILS transmitter failure
- IR failure
- Pitot blocked
- Radio altimeter failure
- Transponder channel failure
- VOR 1
- VOR 2
ATA 34 Navigation
- IR1 total failure
- IR1 position failure
- ADR1 fails.
- IR1 alignment is lost. Unit should be realigned on the ground.
- Captain pitot blocked.
- IR1 pitch discrepancy.
- IR1 bank discrepancy.
- IR1 heading discrepancy.
- IR1 IR disagree.
- IR2 total fails.
- IR2 position failure
- ADR2 fails.
- IR2 alignment is lost. Unit should be realigned on the ground.
- F/O pitot blocked.
- IR2 pitch discrepancy.
- IR2 bank discrepancy.
- IR2 heading discrepancy.
- IR2 IR disagree.
- IR3 total fails.
- IR3 position failure
- ADR3 fails.
- IR3 alignment is lost. Unit should be realigned on the ground.
- Standby pitot blocked.
- IR3 pitch discrepancy.
- IR3 bank discrepancy.
- IR3 heading discrepancy.
- MCDU 1 fails.
- MCDU 1 fails, but is recoverable.
- MCDU 2 fails.
- MCDU 2 fails, but is recoverable.
- FMGC 1 fails.
- FMGC 2 fails.
- GPWS power supply failure
- VOR 1 receiver fails.
- VOR 2 receiver fails.
- ADF 1 receiver fails.
- ADF 2 receiver fails.
- ILS 1 LOC channel receiver fails.
- ILS 1 G/S channel receiver fails.
- ILS 2 LOC channel receiver fails.
- ILS 2 G/S channel receiver fails.
- Localizer transmitter fails.
- Glideslope transmitter fails.
- GPS 1 receiver fails.
- GPS 2 receiver fails.
- Radio altimeter 1 fails.
- Radio altimeter 2 fails.
- EPE exceeds RNP
- TCAS failure
- Transponder channel 1 fails.
- Transponder channel 2 fails.
ATA 35 Oxygen
- Crew oxygen pressure < 400
- Crew oxygen pressure < 800
- Crew oxygen pressure reduced to 30 PSI.
- Crew oxygen pressure reduced to 600 PSI.
- Crew oxygen pressure 2 reduced to 30 PSI.
- Crew oxygen pressure 2 reduced to 600 PSI.
- Oxygen supply valve stuck
- Oxygen supply valve 2 stuck
- Reset passenger oxygen deployed.
ATA 36 Pneumatic
- APU Bleed valve
- Lavatory/Galley fan fails.
- Bleed HP valve of engine 1 is stuck in current position.
- Engine 1 bleed air low temperature.
- Bleed HP valve of engine 2 is stuck in current position.
- Engine 2 bleed air low temperature.
- BMC 1 fails.
- BMC 2 fails.
- Cross bleed valve is stuck in current position.
- APU bleed valve stuck in current position.
- Ram air valve stuck
- Engine 1 bleed valve stuck.
- Engine 2 bleed valve stuck.
- Pack 1 flow control valve disagree
- Pack 2 flow control valve disagree
- Wing duct leak engine 1.
- Wing duct leak engine 2.
- Pylon duct leak engine 1.
- Pylon duct leak engine 2.
- APU bleed leaks.
ATA 46 Information
- ATSU power supply failure
ATA 49 APU
- APU ECB has internal fault.
- APU oil level is below lower limit.
- APU fuel valve is stuck in current position.
ATA 52 Doors
- Door sensor indicates door is not locked.
ATA 70 Engines
- FADEC Eng 1 Channel A fails.
- FADEC Eng 1 Channel B fails.
- FADEC Eng 2 Channel A fails.
- FADEC Eng 2 Channel B fails.
- EIU 1 fails.
- EIU 2 fails.
- Left engine fails.
- Engine 1 fails with damage.
- Left bird strike.
- Engine 1 high N1.
- Engine 1 EGT exceeds limit.
- Left reverser pressurized.
- Left reverser unlocked.
- Left reverser inhibited by maintenance.
- Engine 1 oil pressure below advisory limit.
- Engine 1 oil pressure below limit.
- Engine 1 oil pressure above limit.
- Left nacelle temperature high.
- Engine 1 oil temperature above advisory limit.
- Engine 1 high vibration N1.
- Engine 1 high vibration N2.
- Reverser shutoff valve left
- Right engine fails.
- Engine 2 fails with damage.
- Right bird strike.
- Engine 2 high N1.
- Engine 2 EGT exceeds limit.
- Right reverser pressurized.
- Right reverser unlocked.
- Right reverser inhibited by maintenance.
- Engine 2 oil pressure below advisory limit.
- Engine 2 oil pressure below limit.
- Engine 2 oil pressure above limit.
- Right nacelle temperature high.
- Engine 2 oil temperature above advisory limit.
- Engine 2 high vibration N1.
- Engine 2 high vibration N2.
- Reverser shutoff valve right
- Engine 1 low oil quantity.
- Engine 2 low oil quantity.
ATA 80 Start Faults
- Engine 1 start valve locked in closed position.
- Engine 1 hot start.
- Engine 1 hung start.
- Engine 1 no ignition.
- Engine 2 start valve locked in closed position.
- Engine 2 hot start.
- Engine 2 hung start.
- Engine 2 no ignition.